F-2

Format error codes

QLS-4100 Xe Format Error Codes

1

Field X location error
The X coordinate of a Set Field Location command (FLx,y) is
out of bounds.

2

Field Y location error
The Y coordinate of a Set Field Location command (FLx,y) is
out of bounds.

3

Alphanumeric field font error
The font parameter of a Define Alphanumeric Field Font command
(AFfont,r,w,h,m) is invalid.

4 Alphanumeric

rotation

error

Valid rotations are 0, 90, 180, 270°.

5

Alphanumeric character height error
Valid settings for font height are 10 to 2000 for TrueType® fonts and
1 to 10 for bitmap fonts.

6

Alphanumeric character width error
The range for width values is the same as for height values.

7

Bar-code field type error
The barcode type value of a Define Bar-code Symbol command
(BFtype,r,....) is out of bounds.

8

Bar-code field rotation error
Valid rotations are 0, 90, 180, 270°.

9 Bar-code

height

error

Bar-code height is out of bounds.

10

Bar-code narrow element error
The narrow element value in a Define Bar-code Symbol command is
out of range.

11

Bar-code wide element error
The wide element value in a Define Bar-code Symbol command is
out of range.

12 Bar-code

interpretation

error