Press the + or - key until Gap is displayed.

7

Press the SELECT key. The display will show the following prompt:

8 Press

and

hold the FORM FEED/ADVANCE key until the liner is inside

the sensor bracket. On notched media, temporarily slide the media out so
that it is completely clear of the sensor assembly.

9

Press the SELECT key. The display will show the following prompt:

10 Press

and

hold the FORM FEED/ADVANCE key until the next label is

inside the Gap sensor.

11 Press the SELECT key. The display will show the following prompt:

12 Press and hold the FORM FEED/ADVANCE key until the next gap is

positioned behind the Media Sensor Assembly and in close proximity to
the guide arrow indicated on the center plate.

13 Press the SELECT key. The following message will be displayed:

If calibration was unsuccessful, the following message will be displayed:

Gap
Calibration OK

Place Gap @ Arrow
Then Press Select

Place Media @ Sensor
Then Press Select

Place Liner @ Sensor
Then Press Select

Calibrate

Gap