Appendix, Appendix d: hc34dlm mobile home – Montigo H34DL User Manual
Page 38
H-Series Indoor Gas Fireplace
Page 38
XG0140 - 070714
Appendix
Appendix D: HC34DLM Mobile Home
Gas Control Valve
The following gas control valve is installed on the HC34DLM.
Figure D1.
Sit Nova 820 gas valve
.
HC34DLM-Mobile Home fireplaces:
The mobile home option is factory installed on the HC34DLM gas
fireplaces, and are for use in a manufactured or mobile home.
This appliance may be installed as an OEM installation in a manufactured
home (USA only) or mobile home. This model must be installed in
accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States or The Mobile Home Standard, CAN/CSA Z240 MH
Series, in Canada, and ANSI/NFPA 501A, in the United States. This
appliance is only for use with the type(s) of gas indicated on the rating
plate. A conversion kit is supplied with the unit.
Note:
Electronic Ignition models are not approved for use in mobile or
manufactured homes.
Manifold Pressure
Test Connection
Wall Switch
Power
Generator
Pilot Adjustment Screw
Inlet Pressure
'Hi-Lo' Adjustment Knob
Gas Control Knob (Shown in “Pilot” position)