Installation – Montigo H34DL User Manual
Page 20

H-Series DL Indoor Gas Fireplace
Page 20
XG0140 - 070714
Installation
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
For more information see the Fan Kit Installation Guide included with
the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 25. Wiring diagram for optional fans.
G
L2-WH
L1-BLK
p g
Quick Connect
lu to motor
5/1/60 Supply
G
L1 L2
Wiring for the optional Fan Kit
All H*DL* fireplaces may be equipped with optional fan kits for circulating
heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installing the remote On/Off Wall Switch
The H*DL* gas valve may be connected to a wall switch. Do NOT
connect any external power to the remote switch. The valve will
generate its own power on a millivolt circuit or will draw its power from
an AC Connection inside the fireplace, depending on the model of the
unit. Use only low voltage wire, and DO NOT connect any external
power to the remote switch.
Refer to Figure 22, 23, or 24 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.