beautypg.com

Top of stroke position, Trigger position – Dukane Dual Servo Spin Welder 403570-01 User Manual

Page 38

background image

Dual Servo Spin Welder User’s Manual

Dukane Manual Part No. 403-570-01

Page 3

TOP OF STROKE Position

This button is used to set the vertical position to which
the welder head returns after completing a weld cycle,
as shown in Figure 5-7. A position of 0 corresponds to
the highest position (which is also the machine “home”
position). A non-zero setting indicates that the Top of
Stroke (TOS) position is lower than the home position
by the programmed amount. The TOS position can be
entered directly by pressing the

Position (mm

) field.

Alternatively, the TOS position can be “taught” by first
pressing the

DOWN

button and selecting the

VERT

.

Jog

Speed (Low, Medium, or High)

, then activating the RUN

switches to jog the head to the desired position, and
finally pressing the

Transfer

button to assign the current

jog position (displayed in the

Jog Pos . (mm)

field) as the

TOS Position.

The

Move To

button is used to move the head to the value

displayed in the

Position (mm)

field. After pressing this

button, activate both

RUN

switches and wait for the

value in the

Jog Pos . (mm)

field to match the

Position

(mm)

value.

TRIGGER Position

This button is used to set the vertical position at which the
spin tool and machine head reach the programmed weld
speeds, as shown in Figure 5-8. If Torque Triggering is
disabled (see below), the weld starts at the

TRIGGER

Position. This position should be set slightly higher than
the position at which the parts to be welded start to come
in contact. Above this position, the spin motor is being
accelerated from rest to the weld RPM and the head
is moving rapidly down. After reaching this position,
the spin RPM and vertical speeds are maintained at the
programmed values. The

TRIGGER

Position can be

entered directly into the Position (mm) field or taught
by jogging the head as described in setting the

TOP OF

STROKE

Position.

Figure 5–8

TRIGGER Position Setup Screen in

PRE-WELD Menu

Figure 5–7

TOP OF STROKE Position Setup

Screen in PRE-WELD Menu