View parts – Dukane Dual Servo Spin Welder 403570-01 User Manual
Page 36
Dual Servo Spin Welder User’s Manual
Dukane Manual Part No. 403-570-01
Page 30
bad part means one or more of the measured parameters
was not within the limits set for the weld cycle. The
Time
and
Date
fields indicate the time and date the part
was welded.
Just below the
WELD
label, there are a number of fields
with weld data for the last cycle. The displayed data
lists the:
•
Time
- Weld time (seconds)
•
Rotations -
Number of spin motor rotations
during weld
•
Peak RPM -
Peak spin motor speed (RPM)
•
Peak Torque -
Peak spin motor torque (% of
maximum torque)
•
Energy -
Weld energy (Joules)
•
Orient . -
Welded part angular orientation
(degrees)
•
Weld End -
Weld end vertical position (mm)
•
Peak Thrust -
Peak vertical actuator thrust (% of
maximum thrust)
•
Hold End -
Hold end vertical position (mm)
•
Hold Col -
Hold collapse distance (mm)
•
Cycle -
Total cycle time (seconds)
VIEW PARTS
The
Part Data
button on the right side of the screen
displays seven part reports at a time. Each report
occupies two lines and displays the same information
reported on the
RUN
screen. The report starts with the
last cycle at the bottom and works backwards toward
the top. This is shown in Figure 5–3. The
Page Up
and
Page Down
buttons permit you to scroll through part
data one screen at a time, Press the
RUN
button to
return to the
RUN
screen.
Figure 5–3
VIEW PARTS Screen