The procedure to install the Intercom Distribution Module is as follows:

As shown in Figure 11, there is an “ADDRESS” jumper block located at the top of the rear of
the Selective Call Intercom Distribution Module. This jumper block is used to select the Master
module, and up to three Slave modules when cascading Distribution Modules. Each Selective
Call Distribution Module is shipped with the jumper in the Master position. Use the diagram to
correctly position the jumper to give each Distribution Module a unique address.

Also as shown in Figure 11, there is also a four position terminal block located on the lower
left corner of the rear of the Selective Call Intercom Distribution Module. These are Open
Collector outputs labeled “A” and “B” (ground and output connectors for each). At any
Room Unit, you can configure the “A” Door Strike (“Release”) and/or “B” Alert (“Trigger”)
outputs to be enabled or disabled. Figure 12 shows an example of electronic door release
and/or trigger wiring and Figure 13 shows the screen sequence to enable these functions.









































Figure 11

GND

GND

OUT

OUT

B

A

Door
Strike

Door
Strike
Relay

SCI

Module

(rear view)

Power
Supply

To LCD Module

to wake up LCD Display

and show front door

camera when door bell

is pushed

GND

GND

OUT

OUT

B

A

Door
Strike

Door
Strike
Relay

SCI

Module

(rear view)

Power
Supply

To LCD Module

to wake up LCD Display

and show front door

camera when door bell

is pushed

GND

GND

OUT

OUT

B

A

SCI

Module

(rear view)

Wake ups LCD Display and

shows front door camera
when door bell is pushed

GND

VID_1

TRG

LCD

Module

(rear view)

GND

GND

OUT

OUT

B

A

SCI

Module

(rear view)

Wake ups LCD Display and

shows front door camera
when door bell is pushed

GND

VID_1

TRG

LCD

Module

(rear view)

Figure 12

Door Strike Wiring

LCD Trigger Wiring