Is-0388 rev. b – Legrand IC5004-xx User Manual
Page 2
INSTRUCTION / INSTALLATION SHEET
Selective Call Intercom Patio Unit
IS-0388 Rev. B
301Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
©Copyright 2011 by Legrand All Rights Reserved.
Page 2 of 3
NOTE: Make sure that the included weather proofing gasket is placed as shown in Figure 3.
1. As shown in Figure 3, the first step to installing the
Selective Call Patio Unit is to place the included rear
gasket against the gang or back box, and secure the
gasket in place with the included mounting bracket.
NOTE: Insure that the mounting bracket is installed with
the center tab pointed up, as the Patio Unit will be
“hung” from this tab in a later step.
NOTE: There are slotted holes in the mounting bracket
to allow for leveling of the Patio Unit in case the gang or
back box was installed off level.
2. Use the four provided screws to attach the mounting
bracket to the gang or back box.
3. Pull the Cat 5 cable from the enclosure through the
mounting bracket and terminate the cable with an RJ45
plug and insert the plug into the RJ45 jack on the rear of
the Patio Unit (see Figure 4). Follow the T568A
standards described in Figure 2.
4. Hang the Patio Unit from the top tab on the mounting bracket
and use the provided 1/16” allen wrench to tighten the two set
screws at the bottom of the Patio Unit.
5. Terminate the other end of the Cat 5 cable, at the Selective Call
Intercom Module, with an RJ45 plug using the T568A wiring
standard.
6. Insert the RJ45 plug into any of the eight Room, Patio, or Door
Unit jacks on the Intercom Module, (labeled 1-8).
7. After all Units and Modules are connected, apply power to the
Selective Call Intercom Module and verify system functionality.
All Selective Call Room, Door and Patio Units will be discovered
and shown on each Room Unit LCD.
4. Operation
Figure 3
rear
gasket
center tab
mounting
bracket
set screws
RJ45
jack
Figure 4
front gasket