beautypg.com

Legrand IC5004-xx User Manual

Is-0388 rev. b, Rj-45

background image

INSTRUCTION / INSTALLATION SHEET

Selective Call Intercom Patio Unit

IS-0388 Rev. B


301Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com

©Copyright 2011 by Legrand All Rights Reserved.

Page 1 of 3

1. Introduction

The Legrand Selective Call Intercom Patio Unit, PN IC5004-XX (see
Figure 1
), is weather resistant for outdoor use, and supports responding
to a selective call, initiating a page within the house, local control of the
mute and monitor functions and the ability to talk to a Door Unit. A
separate high quality speaker and microphone provide superior sound
quality. It is available in white (-WH), shiny brass (-SB), antique brass (-
AB), brushed stainless (-BS) and oil-rubbed bronze (-OB).


2. Description

The Patio Unit is a 2-gang product that mounts within an outdoor
weatherproof box (56” from the floor to the bottom of the box). There is
also a two-gang surface-mount box available (P/N IC5006-BK) for unique
or retrofit installation requirements.

3. Installation


Installation of the Selective Call Patio Unit is best accomplished at multiple times during new construction, at
“Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and painted.

A. “Rough-in” steps:

1. Run a Cat 5 cable from the Enclosure where the Selective Call Intercom Module will be installed to the

2 gang box at the Selective Call Patio Unit location.

NOTE: The maximum Cat 5 cable run distance between the SCI Module and another unit (Module,
Door, Patio or Room Unit) is 330’ with the following exception. One Door or Patio Unit may be placed
up to 1000’ (up to 650’ for a Video Door Unit) from the SCI Module, but it needs to be locally powered
and Legrand needs to be informed of and pre-approve this type of installation. If the Cat 5 run is
buried in an underground conduit, it should maintain a 16” separation from any 110VAC wiring.
Additional SCI Modules are recommended to be placed in the same enclosure, powered from the
same power strip, and interconnected with the shortest Cat 5 connections possible.

NOTE: It is important to keep all in-wall Category 5e cable runs at least 12 inches away from AC
electrical cables. If it proves necessary to cross an existing AC cable, do so only at a 90 degree angle.

B. “Trim-out”

steps:


NOTE: All terminations can be correctly completed by following the T568A pin assignments. It is
important that you accurately terminate using T568A at all locations. All terminations of the Selective Call
Intercom System are RJ45 jacks. Refer to Figure 2
for correct T568A termination of RJ45 plugs.







Figure 1

RJ-45

Pin

1 – White/Green
2 – Green
3 – White Orange
4 – Blue
5 – White/Blue
6 – Orange
7 – White/Brown
8 – Brown

RJ-45

Pin

1 – White/Green
2 – Green
3 – White Orange
4 – Blue
5 – White/Blue
6 – Orange
7 – White/Brown
8 – Brown

Figure 2

This manual is related to the following products: