Untwist cable pairs but be sure to leave 1/2" twist in the pairs
between the punchdown block and the start of the cable insulation
(see Figure 9).
•
As shown in the diagram, the Cat 5e cable must be terminated so
that the cable is routed to the punchdown block so that the unit can
be installed into a standard gang box while maintaining proper bend
radius.
•
Following T568A wiring color code, place the pairs firmly into their
appropriate positions on the punchdown block. Ensure that the
individual conductors are seated tightly enough to allow you to
punch them down without having to hold them in place.
•
Using a punchdown tool with a 110 style cutting blade, punch down
each conductor firmly enough to allow any excess conductor to be
cut away by the blade.
•
Insert the Door Unit with the gasket in position and the Cat e5 cable
into the 2 gang box and secure the unit to the box using the 4
included screws.
•
Repeat these instruction for any additional Door Units in your
inQuire™ 1000 Intercom System.
6. Door
Chime
The procedure to install the Door Chime is as follows:
•
The Door Chime circuit board installs onto the rear circuit board of
the Intercom Module.
NOTE: Remove power from the front of the Module before installing
the Door Chime.
Figure 9 - Trim-Out Door Unit(s)
301 Fulling Mill Road, Suite G
© Copyright 2006 by On-Q/Legrand Inc.
Page 9
Middletown, PA 17057
All Rights Reserved
(800)
321-2343
www.onqlegrand.com
•
The 2 gang box should be installed by the masonry
contractor so that it protrudes slightly from the face of the
brick. The box should protrude no less than 1/8" but no
more than 1/4" from the face of the brick.
Vinyl or wood based siding material exteriors:
•
The 2 gang box can be roughed in to the exterior of the
home by first cutting an opening through the exterior base
material of the home that is slightly larger than your 2
gang box.
•
The 2 gang box should then be securely mounted to the
interior framing of the exterior wall and protrudes through
the exterior wall at a depth that will need to be determined
based on the type of siding that will finish the outside of
the wall.
•
Ideally, you would want the siding contractor to use
flashing and make use of J-channel around the perimeter
of the Patio Unit and 2 gang box to provide an attractive
and weatherproof siding installation. Siding contractors
should use flashing and J-channel around the perimeter
of the Patio Unit just as they would with a window.
•
Communication with the siding contractor is highly
recommended to ensure a smooth installation.
•
ONE Cat 5e run is required to operate the Patio Unit.
• Run
ONE Cat 5e cable from the 2 gang box directly to the
enclosure where the Intercom Module will be installed. Label both
ends of your cable run to indicate "Patio Unit". Follow the wiring
guidelines listed in this manual to ensure a quality cable installation.
NOTE: The Patio Unit should be connected to the RJ45 jack that is
labeled 11/PATIO UNIT. This will reduce the maximum number of
Room Units that can be installed from 12 to 11.
5. Door
Unit(s)
The procedure to rough-in the Door Unit(s) is as follows:
•
Typically the Door Unit(s) will be installed on the exterior of the
home next to an entrance door, where you would normally find a
standard doorbell. Verify the Door Unit(s) location(s) with the
homeowner before proceeding.
•
Since the Door Unit will most likely be installed on the exterior of the
home and will be exposed to weather conditions, these instructions
must be followed to ensure a quality installation.
Brick or other cement-based material exteriors:
•
The recommended box to use is a 2 gang outdoor
weatherproof box. This box should be of the type that is
made of heavy die-cast aluminum. Using a heavy die-cast
aluminum box will provide adequate strength in a brick or
cement-based exterior.