beautypg.com

Legrand WKD ProSeries Underfloor Duct Rectangular Floor Box Covers User Manual

Page 4

background image

Wiremold / Legrand
U.S. and International:
60 Woodlawn Street • West Hartford, CT 06110
1-800-621-0049 • FAX 860-232-2062 • Outside U.S.: 860-233-6251
Canada:
570 Applewood Crescent • Vaughan, Ontario L4K 4B4
1-800-723-5175 • FAX 905-738-9721

1 003 807R3 1206

© Copyright 2006 Wiremold / Legrand All Rights Reserved

Bezel

Bezel

Gasket

Recessed Adapter

COMMUNICATION COVER:

1. Attach bezel into trim flange and run communication cables

through the opening. Bezels must be in place prior to pulling
cables to ensure no damage.

2. Wire and insert communication devices into the bezel.

3. Place gasket and cover over the devices making sure

the hinge pin side overlaps the label side of the
communications modules.

4. Install four (4) flat head screws.

CAT. NO. 829PFL SHOWN

CAT. NO. 828COMTCAL SHOWN

CAUTION: Communication devices or blank inserts must be

installed in bezel to provide scrub water seal.

1. Cut a slit in gasket and extend cables through the opening.

2. Determine required openings in plate and remove knockouts

from each half.

3. Fit plate halves around cables and attach with four (4) flat

head screws.

CAT. NO. 829PCK SHOWN

BREAKOUT TAB COVER:

1. Attach recessed adapter to flange.

2. Pull wire through recessed adapter and attach to

keystone jacks. (Keystone jacks not supplied.)

3. Attach keystone jacks to bezels and install into

recessed adapter.

4. Place gasket over recessed adapter.

5. Attach cover with four (4) flat head screws.

BRASS & ALUMINUM COVERS FOR KEYSTONE JACKS: