Bezel
Bezel
Gasket
Recessed Adapter
COMMUNICATION COVER:
1. Attach bezel into trim flange and run communication cables
through the opening. Bezels must be in place prior to pulling
cables to ensure no damage.
2. Wire and insert communication devices into the bezel.
3. Place gasket and cover over the devices making sure
the hinge pin side overlaps the label side of the
communications modules.
4. Install four (4) flat head screws.
CAT. NO. 829PFL SHOWN
CAT. NO. 828COMTCAL SHOWN
CAUTION: Communication devices or blank inserts must be
installed in bezel to provide scrub water seal.
1. Cut a slit in gasket and extend cables through the opening.
2. Determine required openings in plate and remove knockouts
from each half.
3. Fit plate halves around cables and attach with four (4) flat
head screws.
CAT. NO. 829PCK SHOWN
BREAKOUT TAB COVER:
1. Attach recessed adapter to flange.
2. Pull wire through recessed adapter and attach to
keystone jacks. (Keystone jacks not supplied.)
3. Attach keystone jacks to bezels and install into
recessed adapter.
4. Place gasket over recessed adapter.
5. Attach cover with four (4) flat head screws.
BRASS & ALUMINUM COVERS FOR KEYSTONE JACKS: