beautypg.com

8b 8a 7a 7c, 7b 7d, 78a 8b – Legrand Vista Series Archtectural Columns User Manual

Page 3

background image

For attaching to ceiling grid.
An extension add-on accessory
allows the Vista Series to be
used with ceilings up to 15'
[4.6m]. Assemble the outer
tubes to the brace with the
supplied screws. Remove the
main front panel and the two
knockouts on the inside of each
end channel. Slide extension
assembly inside the Vista Unit.
Secure with supplied 1/4"
[6.4mm] bolts by threading
directly into the groove in the
extension tube center. Attach
provide T-bar adapter(s) along
the inside of the extension
tubes with supplied 1/4"
[6.4mm] bolts. Attach to
ceiling grid as shown.

To install in ceilings without
suspended grids
. An extension
add-on allows the Vista Unit to
be used with ceilings up to 15'
[4.6m]. Assemble the extension
tubes to the brace with the
supplied screws. remove the
main front panel and the two
knockouts on the inside of each
end channel. Slide extension
assembly inside the Vista Unit.
Secure with supplied 1/4"
[6.4mm] bolts by threading
directly into the groove in the
extension tube center. Use 3/8"
[9.5mm] threaded rod (not
included). Secure to support
brace using provided
knockouts and appropriate
nuts. Attach to ceiling structure.

8b

8a

7a

7c

7.

Install ceiling plates as shown.

a

Brace

Extension
Tubes

Brace

Extension
Tubes

Align notch
with tab

Overlap Plates
as shown on
both sides

7b

7d

Bend the
remaining
tabs

Bend Tab

7

8a

8b