8b 8a 7a 7c, 7b 7d, 78a 8b – Legrand Vista Series Archtectural Columns User Manual
Page 3
For attaching to ceiling grid.
An extension add-on accessory
allows the Vista Series to be
used with ceilings up to 15'
[4.6m]. Assemble the outer
tubes to the brace with the
supplied screws. Remove the
main front panel and the two
knockouts on the inside of each
end channel. Slide extension
assembly inside the Vista Unit.
Secure with supplied 1/4"
[6.4mm] bolts by threading
directly into the groove in the
extension tube center. Attach
provide T-bar adapter(s) along
the inside of the extension
tubes with supplied 1/4"
[6.4mm] bolts. Attach to
ceiling grid as shown.
To install in ceilings without
suspended grids. An extension
add-on allows the Vista Unit to
be used with ceilings up to 15'
[4.6m]. Assemble the extension
tubes to the brace with the
supplied screws. remove the
main front panel and the two
knockouts on the inside of each
end channel. Slide extension
assembly inside the Vista Unit.
Secure with supplied 1/4"
[6.4mm] bolts by threading
directly into the groove in the
extension tube center. Use 3/8"
[9.5mm] threaded rod (not
included). Secure to support
brace using provided
knockouts and appropriate
nuts. Attach to ceiling structure.
8b
8a
7a
7c
7.
Install ceiling plates as shown.
a
Brace
Extension
Tubes
Brace
Extension
Tubes
Align notch
with tab
Overlap Plates
as shown on
both sides
7b
7d
Bend the
remaining
tabs
Bend Tab
7
8a
8b