3.
Preparation: Before installing activation cover and/or
spacers, repair any cracks or chips around the preset or
floor box opening using a suitable grout or repair
compound. Cover flange is 3/16" [4.8mm].
• Use 1/16" [1.6mm] spacer for 1/4" [6.5mm] tile
installation
• Use 1/16" [1.6mm] and 1/8" [3.2mm] spacers for 3/8"
[9.5mm] tile installation
• Use 1/16" [1.6mm] and 1/4" [6.5mm] spacers for 1/2"
[12.7mm] tile installation
TILE FLOOR ATTACHMENT METHOD USING ACTIVATION COVER AND SPACERS ONLY
4.
Grout: Use grout and/or silicone caulk between edges of
flange and tile.
1/4" Tile & Concrete Install
3/8" Tile & Concrete Install
1/2" Tile & Concrete Install
1/16" [1.6mm]
Spacer
Cover
Concrete
1/4" [6.4mm]
Tile
1/16" [1.6mm]
Spacer
Cover
Concrete
3/8" [9.5mm]
Tile
1/8" [3.2mm]
Spacer
1/16" [1.6mm]
Spacer
1/2" [12.7mm]
Tile
Concrete
Cover
1/4" [6.5mm]
Spacer