12 installing wash nozzle – K-Patents PR-23-SD Generation 1 User Manual
Page 24

Document/Revision No. BP-EN-SDGEN1 1.0 Effective: April 1, 2013
24
4.12 Installing Wash Nozzle
Install the wash nozzle as instructed in the following illustrations: For more thorough
instructions, please refer to K-Patents user documentation or visit the K-Patents website to
see the instructional video on inserting and removing the sensor (www.kpatents.com, PR-23-
SD Safe-Drive™ Operation Guide Video).
WARNING: Always shut the main steam valve before performing any work on the
wash nozzle.
Check the nozzle and valve
before installing the wash
nozzle. Use teflon tape for
all thread connections.
1. Fasten the nozzle to the
3/8” isolation valve (
1).
2. Tighten the nozzle nut
(
2).
3. Carefully open the 3/8”
nozzle isolation valve (
3).
NOTE: If process liquid is
leaking severely, close the
isolation valve immediately
and do not proceed with
nozzle installation.
4. Push nozzle into the
process pipe (
4).
5. Fasten the nozzle guide
(
5).
6. Tighten up nozzle nut (
2).
<
7. Attach steam pipe to 1/4”
ball valve (
1).
8. Open the 1/4” ball valve
(
2).
9. Open the steam supply.
2
3
4
5
1
OPEN
LOCK
1
2