E.max, Cad-on, Glass-ceramic fusion process – Ivoclar Vivadent IPS e.max CAD-on User Manual
Page 32

32
The IPS e.max CAD Crystall./Connnect fusion glass-ceramic is used to 
fuse the IPS e.max CAD veneering structure to the IPS e.max ZirCAD 
framework. The Ivomix (vibrator unit) is used for the processing of the 
fusion glass-ceramic.
Preparation
To prepare for the fusion process, please observe the following procedure:
–  Select the suitable IPS e.max CAD Crystall./Connect material on the basis of the desired tooth shade according to the 
combination table (p. 50).
– Press the Ivomix onto a smooth work surface and switch it on. Please refer to the respective Operating Instructions for
more details on the Ivomix.
– To mix the material, lightly press the closed IPS e.max CAD Crystall./Connect capsule onto the vibrating plate of the
Ivomix for approx. 10 seconds and slightly agitate it.
–  Completely remove the sealing lid from the capsule.
–  Make sure that the material has been properly mixed and that it shows a homogeneous consistency. Use the IPS Spatula 
for this purpose. If required, mix with the IPS Spatula while vibrating the capsule.
– Do not add any liquid.
e.max
®
CAD-on
Glass-ceramic Fusion Process
IPS
IPS e.max CAD Crystall./Connect is already pre-
dosed and ready for use as Single Dose and must not 
be diluted. The addition of liquids results in a  
defective fusion of the restoration. The material's 
consistency is adjusted in such a way that optimum 
fusion is achieved.
Make sure that the material has been properly mixed and that it shows a homogeneous
consistency. Use the IPS Spatula for this purpose.
Completely remove the sealing lid from the capsule.
Lightly press and agitate the closed capsule on the vibrating plate of the Ivomix
for approx. 10 seconds.
Firmly press the Ivomix onto a smooth work surface. If required, slightly moisten the suction 
cups beforehand.
Preparation
Fusion process
Cleaning,
checking
Fusion/
Crystallization
firing
