Layer Thicknesses

The restoration design is key to the success of durable all-ceramic restorations.  
The more attention given to the design, the better the final results and the clinical success will turn out to be. The 
 following basic guidelines have to be observed:

–  The restoration design generated by the software may need to be individually adapted according to the clinical require-

ments using the design tools. 

–  In the case of bridges, a sufficient penetration of the individual bridge elements must be ensured in order to observe the 

minimum connector dimensions in the IPS e.max CAD-on restoration. 

–  During the construction of an IPS e.max CAD-on restoration, the separation into IPS e.max ZirCAD frame-

work and the IPS e.max CAD veneering structure is carried out by the software after the design of an ana-
tomical shape.
  

–  If changes are made to the framework during construction in the milling preview, make sure that no undercuts are created. 

Otherwise, the IPS e.max CAD veneering structure may not be placed on the framework.

–  After the milling process, only the attachment point to the block may be smoothed out on the IPS e.max ZirCAD frame-

work. Further processing is not possible, as this would influence the size of the fusion joint.

The following minimum layer thicknesses are stored in the software and must be observed. Please refer to the
indications (see page 8) for information on the possible restorations.

Crowns

Splinted

crowns

3-unit posterior

bridges

4-unit posterior

bridges

(2 connected bridge pontics

at most)

IPS e.max IPS e.max CAD
veneering structure
minimum layer thickness

circular

0.7

0.7

0.7

0.7

occlusal

0.7

0.7

0.7

0.7

IPS e.max ZirCAD
framework minimum layer
thickness

circular

0.5

0.5

0.5

0.5

occlusal

0.5

0.5

0.5

0.7

Connector dimensions 

9 mm

2

12 mm

2

Dimensions in mm