Application Procedure

– Permanent Cementation

The Ti base is screwed on the model analog. The relative position to the ceramic

structure is marked with a waterproof pen.

The bonding surface can be carefully blasted according to the instructions of the

manufacturer.

E.g. silicone (Virtual Extra Light Body Fast Set) is applied in order to protect the

emergence profile and the screw channel.

Removal of the silicone and subsequently cleaning with ultrasound in a water bath

or with the steam jet.

Monobond Plus is applied to the clean bonding surface and allowed to react for

60 s. After the reaction time, any remaining residue is dried with blown air that is

free of water and oil.

The screw channel is sealed with a foam pellet or wax.