Restoring the data – Gasboy Quarles NBS User Manual
Page 29

MDE-4643 Quarles NBS Configuration and Software Installation Manual · March 2007
Page 25
Restoring the Data
To restore the data, proceed as follows:
1
Type NBS–I. When prompted, save the changes and reboot the system.
2
Insert the customer floppy.
3
Type NBS–R A:NBSQUARLES.TXT and press Enter.
4
Type NBS–M and configure the modem.
5
Press S to save and press Return.
Note: Do not start the reboot process.
6
Type RESTORE EV FR A:SYSBACK.DTA and press Enter.
7
Sign on and type NBS–X. Load the appropriate product cross reference information.
8
Type NBS–E and load the appropriate terminal number.
9
Set the maximum time in fall back to 120.
10
Type SYS_PAR and set the appropriate system ID number on
11
Reboot the system to complete the installation.
12
“Site Configuration” on page 6
to ensure that all the settings are correct.
13
Run several test transactions and confirm the following:
• Authorization is successful
• Appropriate dispensers are activated
• Receipt information is correct