Islander II With Key Option Conversion
8
04/15/03
POWER ON AND TEST
1. When you have finished installing the conversion kit, turn on the power for the Islander unit.
If the unit does not power up, turn the power off and verify all cables are on and in the correct
locations. Turn on the power for the Islander unit again.
If the unit still will not power up, contact Gasboy Technical Service at (800)444-5529.
2. Using a calibrated multimeter, measure the +5 VDC between TPI (+) and TP2 (-). The voltage
should be +5.05
±
.1 VDC. Adjust if necessary. Measure the + 12 VDC between the red (+)
and black (-) wires on the DC OUTPUT connector of the power supply. The voltage should be
between +11.0 VDC and +14.0 VDC.
3. Move the toggle switch S3 to the self-test or down position.
4. Press the Start Over button and Self Test Mode will appear on the display.
5. Press
“.” on the keypad and the display will show Insert Key. Insert a programmed test key
and turn it to the left. The display will show CRC1 OK, CRC2 OK followed by the key data.
Continue to press the Start Over button until all key data is shown and you return to the Self
Test Mode prompt. Remove your test key from the receptacle. NOTE: If you have dual key
receptacles, repeat self test to test both receptacles.
6. Remove the test key and move the toggle switch S3 to the on-line or up position and press the
S1 reset button.