Gasboy NPT Disch Kit User Manual
Introduction
MDE-4533 Instructions for Installing Atlas™ NPT Discharge Kit (M06648K001) • December 2005
Page 1
Introduction
This document provides instructions for installing the NPT Discharge Kit (M06648K001) on
Atlas
™
units.
Intended Users
The intended users of this document are Authorized Service Contractors (ASCs), Software
Quality Assurance (SQA) and Manufacturing personnel.
Abbreviations and Acronyms
Term
Expansion
ASC
Authorized Service Contractor
SQA
Software Quality Assurance
The following table contains a list of acronyms used in this document.
Warranty
For information on warranty, refer to Gasboy’s Warranty Policy Statement - MDE-4255. If
you have any warranty-related questions, contact Gasboy’s Warranty Department at its
Greensboro location.
Required Tools
• 13 mm socket and ratchet
• Pipe wrench
• Channel-lock pliers (2 sets or other means of tightening 2 fittings, for example vise)
MDE-4533
Instructions for Installing Atlas
™
NPT
Discharge Kit (M06648K001)
December 2005
Document Outline
- Introduction
- Important Safety Information
- Installing Atlas NPT Discharge Kit (M06648K001)
- 1 Remove the existing discharge fitting from the exterior of the unit, copper discharge tube and meter discharge fitting.
- 2 Apply pipe sealant to the threads of the 1-inch pipe nipple (R11495-123).
- 3 Insert the nipple into the discharge fitting (M04624B020) and tighten it.
- 4 Apply oil to the O-ring (N16891-32) and insert it into the O-ring groove in the meter discharge.
- 5 Slide the discharge mounting bracket (M06642B001) over the nipple.
- 6 Inserting the open nipple end through the discharge hole in the frame, insert the discharge fitting (M04624B020) into the meter discharge and place and tighten the (2) screws (M00415B011).
- 7 Slide the discharge blanking plate (M06432A002) over the nipple protruding on the outside of the unit so that the attached clinch-studs are inserted through the frame.
- 8 Slide the discharge mounting bracket (M06642B001) to the frame capturing the clinch studs on the blanking plate through the holes in the discharge mounting bracket. Place (4) M8 flanged nuts (M00414B003) to the studs and tighten.
- 9 Slide the U-bolt (M00703B001) through the holes on top of the discharge mounting bracket so that it captures the nipple. Place (2) M8 flanged nuts (M00414B003) to the U-bolt and tighten them.
- 10 Slide the discharge grommet (028960) over the end of the nipple to where the rear face of the grommet is against the blanking plate.
- 11 Apply pipe sealant to the threads of the 1-inch painted elbow (024895), screw it onto the nipple and tighten the elbow.
- 12 Reattach hoses and hardware. After purging air from unit, check for leaks.