Introduction
This manual provides instructions for removal of an existing filter adapter and installation of a
Cold Weather field upgrade kit for the External Filter Option. The blue fluorosilicone gaskets
in this kit are intended for units operating in environments with temperatures below 0 degrees
F (-17 degrees C). The filter adapter in this kit incorporates a special groove design necessary
for the cold weather gasket to function properly. The modified adapter and blue cold weather
fluorosilicone gaskets are key parts for the proper operation of this kit.
Kit Number
Filter Type
Pump Model
M06575K001
Hydro (particulate and water)
216A, 9510 and 9850A
M06575K002
Standard (particulate only)
This kit contains parts for the following models.
Required Reading
The installer must read and understand all instructions, safety warnings and precautions before
beginning. The installer must also be familiar with:
• This manual
• NFPA 30A, The Automotive and Marine Service Station Code
• NFPA 70, The National Electric Code
• Applicable federal, state and local codes and regulations
Failure to do so may adversely affect the safe use and operation of the equipment.
Note: This kit must be installed by a Gasboy Authorized Service Contractor (ASC) to ensure
warranty.
Required Tools
The following tools are needed to install this kit:
• 2 pipe wrenches
• UL
®
classified gas and oil resistant pipe compound
MDE-4527
Gasboy Cold Weather External Filter
Field Upgrade Kit
October 2005
Document Outline
- Introduction
- Important Safety Information
- Removal and Installation Instructions
- Parts In Kit
- 1 Ensure power to unit has been removed and locked out.
- 2 Release any residual pressure through the hose nozzle into an approved container.
- 3 Place approved catch pan and absorbent material to catch any fuel.
- 4 Wearing safety goggles, carefully remove existing filter adapter. Save piping for reuse.
- 5 Remove and discard black gaskets that come with come with the filters.
- 6 Install new filter adapter (P/N 025903, rev D or later) onto piping using UL approved gas and oil resistant pipe compound on male threads only.
- 7 Install filter elements (PN/ 0259000 or P/N 0259001) using the blue fluorosilicone gaskets (M06450B001) in the kit.
- 8 Install the remaining piping with approved pipe compound.
- 9 Dispose of any fuel or absorbent material properly.
- 10 Put unit into service and check for leaks and proper operation.