9800A won’t activate in on-line mode. When the pump handle is thrown, the displays do
not go through reset sequence.

Possible Cause

Checks

Corrective Action

9800A is not communicating to
the GASBOY CFN system.

Verify that the 9800A is
communicating.

Perform actions listed under
9800A is not communicating to
the GASBOY CFN System.

9800A won’t activate in
standalone mode.

Verify that the 9800A works in
standalone mode..

Close SW1-2 on the CPU
PCB, turn the power switch off
and on, then perform the
actions listed under 9800A
won’t activate in standalone
mode. Open SW1-2, then turn
the power switch off and on
before returning to this page.

CFN system data loaded
incorrectly.

Verify that all CFN system
data is loaded correctly
(authorization codes, product
codes, pump table, etc.)

Reload system data, if
incorrect.