MDE-4320 Gasboy UHF Pump, Blackmer® XU2A Rebuild Kit Installation Manual • June 2004

Damaged Vanes

• Foreign objects entering the pump
• Running the pump dry for extended periods of time
• Cavitation
• Viscosity too high for he vanes and /or the pump speed
• Incompatibility with the liquids pumped
• Excessive heat
• Worn or bent push rods or worn push rod holes
• Settled or solidified material in the pump at start-up
• Hydraulic hammer - pressure spikes
• Vanes installed incorrectly (see "Vane Replacement").

Broken Shaft

• Foreign objects entering the pump
• Viscosity too high for the pump speed - EC Rotor & Shaft

required for fluid viscosities over 20,000 SSU

• Relief valve not opening
• Hydraulic hammer - pressure spikes
• Pump/driver misalignment
• Excessively worn vanes or vane slots
• Settled or solidified material in the pump at start-up

Mechanical Seal Leakage

• O-rings not compatible with the liquids pumped
• O-rings nicked, cut or twisted
• Shaft at seal area damaged, worn or dirty
• Ball bearings over greased
• Excessive cavitation
• Mechanical seal faces cracked, scratched, pitted or dirty

Symptom

Probable Cause