Model 247-005
1. Remove the four screws from the front panel. Remove the front panel and set aside.
N
OTE
: There is a 7-foot half-modular telephone cord attached to the PCBA on the rear.
2. There are four mounting holes in rear enclosure. Mount the enclosure to the wall using either four
¼-20 machine screws with washers and nuts or four #14 wood screws of the appropriate length,
depending on the mounting surface.
3. Drill a 0.688-diameter hole at either drill spot on the bottom of the rear enclosure, and attach the
gland bushing.
4. Fish the free end of the telephone cord through the gland bushing.
5. Connect the telephone line to the customer-supplied telephone line surge suppressor (if applicable)
and modular jack (USOC RJ11 or CA11A) provided with the unit.
N
OTE
: The modular jack may be mounted inside the telephone. Telephone line connections directly
to TB1 are acceptable.
6. Allow the telephone a minimum of 35 seconds to initialize.
Figure 6. Model 247-005 SMART Auto-Dial Telephone
- 247-005 SMART Auto-Dial Handset Telephones 277-005 SMART Auto-Dial Handset Telephones 257-005 SMART Auto-Dial Handset Telephones 226-005 SMART Handset Telephones with Keypads 246-005 SMART Handset Telephones with Keypads 276-005 SMART Handset Telephones with Keypads 256-005 SMART Handset Telephones with Keypads