9 motor lead harness, 1 removal, Limitorque actuation systems – Flowserve MX-85 Actuator User Manual
Page 85: Flow control, Figure 5.9 – motor lead assembly
![background image](https://www.manualsdir.com/files/784855/content/doc085.png)
Flow Control
Limitorque Actuation Systems
FCD LMAIM1341-00
MX-85/140 Maintenance and Spare Parts
77
5.9 Motor Lead Harness
Figure 5.9 – Motor Lead Assembly
�
�
�
�
�
�
��
��
��
��
��
�����
��������
���������������
��
��
�
�
�
�
����������������
����������������
�������������
������������
�����������������
��
��
��
�
�
�������������
�����������������������
����
5.9.1 Removal
First Remove
1. Remove motor (subassembly #4). (See Section 4.1.1)
2. Remove Accutronix control panel (subassembly #7). (See Section 5.1.)
3. Remove control module (subassembly #15). (See Section 5.2.1)
4. Remove contactor assembly (subassembly #8). (See Section 5.6.1)
STEP 1
If worm shaft assembly (subassembly #3) is still
mounted in unit, remove the four screws (#3-9)
and rotate cap (CCW) to rotate cap tab away from
motor lead seal.
1
Cap
tab
Motor
lead
seal
STEP 2
Remove motor lead harness by threading the
harness back through housing and out motor
end. Work the three connectors out through the
hole/slot in the housing one at a time.
2