Flowserve MX-85 Actuator User Manual
Page 22
![background image](https://www.manualsdir.com/files/784855/content/doc022.png)
Flow Control
Limitorque Actuation Systems
14
MX-85/140 Maintenance and Spare Parts
FCD LMAIM1341-00
STEP 8
Install bolts (#10-10) to secure the actuator to the
thrust base assembly (#10).
8
STEP 9
a
WARNING: Hazardous Voltage! Turn off all
power sources before rewiring incoming power
leads L1, L2, L3, and control wiring in the
terminal block.
Reconnect incoming power leads L1, L2, L3, and
control wiring to the terminal block. Restore power
source when ready for operation.
3.2.3 Removal (Type A1/A1E Base)—Actuator and thrust base as a unit
STEP 1
a
WARNING: Hazardous Voltage! Turn off all
power sources to actuator before removing
actuator from mounting plate. Power sources
may include main power or control power.
If necessary, disconnect incoming power
leads L1, L2, L3, and control wiring from the
terminal block.
Actuator + thrust base removal
Remove the bolts that secure the actuator and
thrust base (#10) to the mounting adapter.
1