DNF Controls ST420-VSS User Manual
Page 13
ST420-VSS User Manual
Page 9 of 21
g) Set Spyder Status Polling Rate
This sets the rate at which the Shotbox gets status information from the
Spyder. The number that is displayed is in 10s of milliseconds. The
default polling rate is 50, which is equal to 500ms (milliseconds) or 0.5
seconds.
NOTE- It is recommended that the polling rate be left at the default
value of 50 (500ms).
1) Press the [POLLING RATE] key (shotkey #11).
2) The POLLING RATE is displayed in three keys in the upper right
section of the keyboard.
3) Enter the Polling Rate using the displayed numeric keypad on the
Shotbox.
4) Press the [ENTER] key to save the entered Polling Rate.
OR
Press the [ESC] key or [BACK] key (shotkey #30) to exit without
saving changes.
h) Toggle Spyder Status Polling ON/OFF
NOTE- It is recommended that the polling be set to ON.
1) The POLLING ON/OFF is displayed in the key. Each key press will
toggle the function.
2) Press the POLLING key until it shows "POLLING ON".
NOTE- After exiting the Setup Menu, the six control key LEDs—
SHIFT through ENTER – will turn on to indicate that there
is no communication between the Shotbox and Spyder.
The six control key LEDs will remain off while the Shotbox
successfully communicates with Spyder.
The six control key LEDs will NOT change state in the
Setup Menu.