beautypg.com

Pbio enable/disable, Production switcher pbio trigger values, On the st400 – DNF Controls 2044CL-L-PBIO User Manual

Page 13: Grass valley group production switcher, Sony production switcher

background image

2044CL-L-PBIO, 300 Clip Fast Access System, Louth Protocol

Page 13 of 27


12. PBIO ENABLE/DISABLE

ON THE ST400


Press the {PBIO} softkey to enable or disable PBIO. When disabled, the ST400 will ignore all
Pbus commands. When enabled, the ST400 will respond to all Pbus commands.

When enabled and Pbus commands are received, the softkey’s LED will flash.

13. PRODUCTION SWITCHER PBIO TRIGGER VALUES


The Production Switcher outputs a Peripheral Bus trigger at specific Timeline key frames, as
programmed by the operator. The 2044CL performs a specific function for each trigger value:


GRASS VALLEY GROUP PRODUCTION SWITCHER


Trigger Value

Mode

0

Play (if OUT point is specified, stop at OUT, if clip ends with
“*”, Loop Play)

1

Recue to beginning of clip

2

Slo-mo using ST400 Preset Speed

3

Reverse Play

4

Still Frame

5

Loop

6

Record

7 or greater

Play

SONY PRODUCTION SWITCHER

Trigger Value

Mode

0

Recue to beginning of clipPlay

1

Play (if OUT point is specified, stop at OUT, if clip ends with
“*”, Loop Play)

2

Slo-mo using ST400 Preset Speed

3

Reverse

Play

4

Still

Frame

5

Loop

6

Record

7 or greater

Play

To control more than one VTR, enable the Peripheral Device Address for each VTR. The Trigger
value will be sent to the enabled devices.
OR

GANG the required VTRs on the ST400. See FUNCTION TABLE for GANG instructions.
Enable the Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to
the enabled VTR. The other VTRs in the GANG will perform the same action.