beautypg.com

C. on the production switcher, Recue clip, Clear cue points – DNF Controls 2044CL-L-PBIO User Manual

Page 11: A. on the st420 shotbox, B. on the st400

background image

2044CL-L-PBIO, 300 Clip Fast Access System, Louth Protocol

Page 11 of 27

c.

ON THE PRODUCTION SWITCHER


RECALL the desired REGISTER.

The ST400 will automatically load the Learned clips on the Learned VTRs, set the
Learned IN and OUT points, cue the clips to the Learned IN point, set the Learned GANG
mode.

8.

RECUE CLIP

a. Press

[RECUE]. If an IN Point is marked (the IN indicator is on), the clip will RECUE to

the IN Point.


b. Press

{CUE OUT} to cue to the marked OUT point.


9.

CLEAR CUE POINTS

a.

ON THE ST420 SHOTBOX

1)

Select the desired BANK by pressing the desired bank key.


2)

Press and hold the [SHIFT] key.


3)

Press the desired Shotkey to be cleared.

After the cue point is cleared, the Shotkey will be blank.

OR

b.

ON THE ST400

1)

Select the cue point to be cleared using [NEXT CUE], [LAST CUE], or
manually entering the cue point number.


2) Press [SHIFT] + [LEARN].
The

{CLR-CUE} softkey will be displayed on the bottom of the display.


3) Press

the

{CLR-CUE} softkey to clear the cue point. The cue point will be

cleared and the display will return to the normal screen.

OR

Press [ESC] to escape without clearing.