Pbio register mapping to shotlist location, Transferring cuelists – DNF Controls 2034CL-SX-PBIO User Manual
Page 15

15
2034CL-SX-PBIO, 300 Clip Instant Access System, Sony SX Protocol
15. PBIO
REGISTER
MAPPING TO SHOTLIST LOCATION
Register 0-30 Î
Cue Point 0-30
Register 31-60 Î
Cue Point 101-130
Register 61-90 Î
Cue Point 201-230
Register 91-99 Î
Cue Point 301-309
16. TRANSFERRING
CUELISTS
The TRANSMIT CUELIST function allows you to transmit your list of Cue Points to a
PC, using the provided utility software on the PC, or to another ST300. Transfer to a PC
requires OpSuite 3.0 software, which runs on a Windows-based computer. Contact DNF
Controls for more information.
To Transmit Cue Points to the ST300:
1.
Connect the VTR 4 connector on the rear of the ST300 to the VTR4 connector of
the receiving ST300 using an RS422 9-pin cable with TX and RX lines crossed.
(A “turnaround” cable)
2.
Press [MENU] and scroll the Wheel until
“Transmit CUE List? YES=Enter, Exit=ESC” is displayed.
3. Press
[ENTER] to start transmitting.
The Display shows “Waiting to transmit” on the first line.
4.
When the Receiver is ready, transfer starts automatically.
The Display now shows ”Transmitting cuelist”.
5.
After the transfer is over, the display shows “Transfer is over” for one second
and then shows “Waiting to transmit” again.
6.
Connect another ST300 to transmit the list again
OR press [ESC] twice to exit the MENU mode.
To Transmit Cue Points to the PC:
1.
Connect the VTR4 connector on the back of the ST300 to one of the COM ports
on the PC using a RS422 to RS232 adapter.
2.
Repeat steps 2-6 of the TRANSMIT CUE POINTS to the ST300 section.