Troubleshooting, B. st420 (shotbox), Rs422 serial connector – DNF Controls 2034CL-TO-PBIO User Manual
Page 24: Power connector, St420 troubleshooting
![background image](https://www.manualsdir.com/files/781645/content/doc024.png)
24
2034CL-TO, 300 Clip Instant Access System
Pinnacle Thunder Protocol,
PBIO Option
b. ST420
(SHOTBOX)
Power:
90 VAC to 265 VAC adapter supplied with IEC connector
Size:
[L” x W” x H”] 11.5” x 6.5” x 1.75” (front) 3.5” (rear)
Weight:
4
lbs.
Rear Panel Connectors:
Out ………………… (DB9F)
GPI
…………………
(DBF15F)
Power
………………
(DB9M)
Aux
…………………
(DB9F)
RS422 SERIAL CONNECTOR
9-Pin D-Type, Female
Pin #
1
Frame Ground
6
Transmit Common
2
Transmit
A
Î
7
Transmit
B
Î
3
Receive
B
Í
8
Receive
A
Í
4
Receive
Common
9
Frame
Ground
5 Spare
POWER CONNECTOR
9-Pin D-Type, Male
Pin #
1
+5v DC
6
No Connection
2
+5v
DC
7
Ground
3
Ground
8
Ground
4
No
Connection
9
Ground
5 No
Connection
29. TROUBLESHOOTING
ST420 TROUBLESHOOTING
a.
All keys are RED - No communication with ST300.
b.
All keys are dark - No communication between the ST300 and the Video Server.
c.
The version of the ST420 must comply in the software version with the ST300 it is
connected to.
To determine the software version of the ST420 do the following:
1)
Press
[SHIFT] + [STOP] + [PLAY].
The key that displays the current version is RED.
2)
The ST420 displays:
“SELECT ST300 V2.1 or V2.0 or V3.0.”