beautypg.com

Trigger, Grass valley group, Sony – DNF Controls 2034CL-TO-PBIO User Manual

Page 14

background image

14

2034CL-TO, 300 Clip Instant Access System

Pinnacle Thunder Protocol,

PBIO Option

17. TRIGGER


The operator fires a trigger using either the Timeline or Run function on the production switcher.
The ST300 puts the Video Server into these modes based upon the trigger value:

GRASS VALLEY GROUP


Trigger Value

Mode

0

Play

1

Recue to beginning of clip

2

Slo-mo using ST300 Preset Speed

3

Reverse Play

4

Still Frame

5

Play

6

Record

7

Loop

8 or greater

Play

SONY


Trigger Value

Mode

0

Recue to beginning of clip Play

1

Play

2

Slo-mo using ST300 Preset Speed

3

Reverse Play

4

Still Frame

5

Play

6

Record

7

Loop

8 or greater

Play


To control more than one VTR, enable the Peripheral Device Address for the required VTRs. The
Trigger will be sent to the enabled devices.
OR

GANG the required VTRs on the ST300. See SETUP MENU section for GANG instructions.
Enable the Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to
the enabled VTR. The other VTRs in the GANG will perform the same action.