Fault
Name
Fault Descriptions
Corrective Actions
Communication Error
1. Check the RS485 connection between the AC
motor drive and RS485 master for loose wires
and wiring to correct pins.
2. Check if the communication protocol, address,
transmission speed, etc. are properly set.
External Base Block.
(Refer to Pr. 8-06)
1.
When the external input terminal (B.B) is
active, the AC motor drive output will be
turned off.
2. Deactivate
the
external input terminal (B.B) to
operate the AC motor drive again.
Dimensions are in mm [inch]
I
G
H
D
A
C
F
B
E
5.0 [0.20]
Model Name
A
B
C
D
E
F
G
H
I
002S11A/21A/23A
85.0
[3.35]
148.0
[5.83]
88.0
[3.47]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
- - -
004S11A/21A/23A
85.0
[3.35]
148.0
[5.83]
102.0
[4.02]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
- - -
004S43A/43E,
007S21A/23A
85.0
[3.35]
148.0
[5.83]
124.0
[4.89]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
- - -
007S43A/43E
85.0
[3.35]
148.0
[5.83]
126.0
[4.96]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
- - -
002S21E, 004S21E,
007S21E, 015S23D
85.0
[3.35]
148.0
[5.83]
127.0
[5.00]
74.0
[2.92]
133.7
[5.27]
5.8
[0.23]
- - -
002S11B/21B/23B
85.0
[3.35]
148.0
[5.83]
88.0
[3.47]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
73.0
[2.88]
16.0
[0.63]
67.8
[2.67]
004S11B/21B/23B
85.0
[3.35]
148.0
[5.83]
102.0
[4.02]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
73.0
[2.88]
16.0
[0.63]
67.8
[2.67]
004S43B,
007S21B/23B
85.0
[3.35]
148.0
[5.83]
124.0
[4.89]
74.0
[2.92]
132.2
[5.21]
5.8
[0.23]
73.0
[2.88]
16.0
[0.63]
67.8
[2.67]