Appendix b, International installation, Appendix b: international installation – Daktronics GPR-12EV-RGB User Manual
Page 59

International Installation
47
Appendix B: International Installation
The power source is the biggest difference
between domestic and international
applications. International displays run on 240
VAC.
Terminating single-phase power to the
internal power termination panel:
Daktronics’ displays used in international
applications are equipped with different power
termination panels than domestic displays.
However, the termination method is similar to
domestic termination discussed in Section 3:.
1. Open the display as explained in
Section 6: and locate the power
termination panel.
2. Route the cable through conduit to
the back of the display. Remove
the rubber plug from the
3
/
4
"
knockouts for access, being careful
not to damage internal
components.
3. Remove the cover of the power
termination panel.
4. Connect the neutral wire to the
neutral lug and the live wire to the
Line 1 lug, as shown in Figure 41.
5. The ground wire connects to the
grounding bus bar.
Figure 41: 240 V Single-Phase Power Termination