Mlc diagnostics, Temperature sensor diagnostics, Troubleshooting display problems – Daktronics GPR-12EV-RGB User Manual

Page 36: Module and led problems, 3 mlc diagnostics, 4 temperature sensor diagnostics, 5 troubleshooting display problems

background image

30

Diagnostics and Troubleshooting

7.3 MLC Diagnostics

Each multi-line controller (MLC) contains

four red diagnostic LEDs, as shown in

Figure 30. When fiber is properly connected,

the LED labeled DS23 (left side) will be off

and the other LEDs will be on

7.4 Temperature Sensor

Diagnostics

If the display includes a temperature sensor,

the temperature sensor board will provide

diagnostic information. The temperature

sensor board, shown in Figure 31, is located

inside the temperature sensor housing

which hangs near the display. A flashing

DS2 LED indicates that unit is sending

temperature information. It also indicates

that the unit has power.

Refer to Appendix B for temperature sensor mounting and

connections.

7.5 Troubleshooting Display Problems

Some common symptoms that may be encountered in a display and

simple steps to resolve them follow. Solutions are organized by

priority, so try them in order.

Troubleshooting may require removing or replacing modules. Refer

to Section 6: for instructions on this procedure. Make sure power

and signal cables are reconnected correctly and latches are tightly

closed when replacing modules.

Consult the Venus

®

1500 software Help file when content problems (including brightness,

message, temperature, and testing) occur. Click the Application button in the top left corner

of the Venus

®

1500 Home page and click Help.

Module and LED problems

One or more LEDs will not light

Check/replace ribbon cables on the module.

If that does not help, the module may need to be replaced.

Figure 30: MLC Diagnostic LEDs

Figure 31: Temperature

Sensor Board