beautypg.com

5 annual inspection xe "annual inspection, Annual inspection, 5 annual inspection – Daktronics GPR-12EV-RGB User Manual

Page 33

background image

Maintenance

27

6.5 Annual Inspection

Complete a yearly inspection to maintain safe and dependable display operation. Open the

display to visually inspect the cabinet interior and the components. Refer to Section 6: for

directions to access the interior. The inspection should address the following issues:

Inspection item

Possible corrective measures

Loose bolts, screws, rivets

Tighten or replace, as required.

Dust around fans, on
cabinet bottom

Vacuum or carefully wipe away.

Water intrusion or stains

Replace weather stripping.

Tighten module latches.

Place silicon sealant around all locations where water might enter.

Replace damaged electronic components.

Paint corrosion by footings,
tie points, ground rods

Check the metal footings for structural integrity.

Replace and/or repaint as necessary.

Check ground wire connections at ground rod and ground lug.

Filters

At any inspection, check filters.

Clean or replace filters as necessary.