RS422

One end of the signal cable should be terminated to the surge suppressor terminal
block in the display labeled “IN RS422” (TB1). Drawing A-88427 is an example of
the termination panel. The opposite end is terminated at the signal converter
(Daktronics part number 0A-1127-0237). Refer to Drawing A-92681 shows an
example system riser using the RS422 signal termination.

Figure 19: RS422 Signal Converter Connections

Signal Converter (J4/J5)

Field Cabling

Terminal Block (Data In)

Pin 1 (GND)

Red

Pin 1 (GND)

Pin 2 (RX-P)

Black

Pin 2 (TX-P)

Pin 3 (RX-N)

Brown

Pin 3 (TX-N)

Pin 4 (TX-P)

White

Pin 4 (RX-P)

Pin 5 (TX-N)

Blue

Pin 5 (RX-N)

Green

Pin 6 (GND)

Pin 6 (GND)

Shield (Bare)

N.C.

Electrical Installation

3-8