Troubleshooting, Troubleshooting -7, 6 troubleshooting – Daktronics DF-1060 User Manual
Page 29
Display Maintenance
3-7
and Troubleshooting
3.6 Troubleshooting
This section lists potential problems with the display, indicates possible causes, and
suggests corrective action. This list does not include every possible problem, but it
does represent some of the more common situations that may occur.
Symptom/Condition
Possible Cause
Garbled display
Internal driver logic malfunction
Control console malfunction
Digit will not light
Black wire to digit broken
Poor contact at driver connection
Driver malfunction
Segment will not light
Broken LED or connection
Driver shift register failure
Broken wire between driver and digit
Poor contact at driver connector
Segment stays lit
Driver shift register failure
Short circuit on digit
Data appears in the wrong place
on the display, wrong data on a
particular line of the display
Incorrect address settings on drivers
(Refer to “Power On Self-Test” in the
following section, and consult tables to set
correct addresses.)
Some DataMaster displays have their own built-in troubleshooting mechanism.
Failures that may occur in the display driver are described using codes. In the event a
sign malfunctions, a failure code registers by displaying an “Ex” value on the first
two digits of the display. “E” simply indicates an error, and the letter “x” represents
the actual code number. Refer to the following table for a description of each failure
code and for possible solutions. Not all error codes are applicable to all displays.
Note: The LCD screen on the DataMaster 100 controller will not show the failure
codes described in the following table. Failure codes will be displayed only on the
Data Master sign.