background image

Figure 4: DataMaster Driver Enclosure with 16-Column Driver

To gain access to the driver enclosure, open the access door and remove the cover
from the enclosure. Refer to the electrical specifications drawings for the access
location for your sign.

Connect the power and signal cables at the appropriate locations on the driver
enclosure panel, shown in Figure 4 and in Drawing A-198033.

The power feeder circuit connects directly to a terminal block in the driver enclosure.
The block is located in the bottom center of both types of driver enclosure. Refer to
the driver illustrations and the schematics, Drawings A-184475 and A-179599, for
wiring details.

Route signal cabling to the terminal block on the lower left edge of the enclosure
(see Figure 4). The connections are labeled to permit easy installation. (In the 16-
column enclosure, the signal block is at bottom center.) For signal cable, Daktronics
recommends 2-pair shielded cable, 22 AWG (Daktronics part number W-1234).

Mechanical and Electrical

2-5

Specifications