Section 7, Signal cable installation, Primary-mirror signal connection – Daktronics Rear-Ventilated GalaxyPro GP3 Series User Manual
Page 18: Sectional display signal connections, 1 primary-mirror signal connection

13
Section 7: Signal Cable Installation
This section describes signal cable installation for GalaxyPro
®
GP3 series displays. There are several types
of data signal connections that may need to be made depending on the size of the display and number of
sections.
7.1 Primary-Mirror Signal Connection
For data to get from the Primary display to the Mirror display, the fiber interconnect cable must
be connected. This cable typically comes attached to the back of the display.
1. Locate cable and unpackage.
2. Connect one end of the cable to J34 on the
back of the Primary display, as shown in
3. Connect the other end of the cable to J32 on
the back of the Mirror display.
4. Coil up any excess cable and secure it to
prevent vandalism and weather-related
damage.
Note: Anchor points are found on each fan
hood for securing excess cable.
7.2 Sectional Display Signal Connections
For sectional displays, data is transmitted from one
section to the next through fiber cables connected to the
outside of each section.
Each section has multiple jacks labeled either A or B.
Refer to drawing B-1033700 in the back of this manual for
correct cable routing between display sections. A label
on the display’s back also illustrates how to connect the
cables. An example of this label is shown in Figure 14.
Figure 13: Signal Out Quick-Connect Jack
Figure 14: Example Cable Connection
Label on Back of Display
Signal Cable Installation