Backup mode, Status commands, Configuration status – Comtech EF Data DT-4500 Series User Manual
Page 89: B.6.3.3 b, B.6.4 s, B.6.4.1 c
DT4500 Series Down Converters
MN/DT4500.IOM
Remote Control
Revision 1
71
B.6.3.3 B
ACKUP
M
ODE
This command allows the user to force a backup condition for maintenance and test
purposes. This command must be sent to the converter designated as the backup
Converter (i.e., “BU”). When activated this command forces the backup Converter to
assume the state of the specified chain converter and forces the chain converter offline.
Command
Details
Initiate a Backup:
Confirmation: >DEV/FBU_xx_y'cr''lf'] Where: xx = 01 to 12, converter number y = ‘F’ to force a backup ‘N’ to remove a backup Retrieve Backup Confirmation: >DEV/FBU_xx_zzzzz'cr''lf'] Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter number is not displayed. zzzzz = ‘NONE’ if no backup active = ‘ACTIVE’ if an automatic backup has occurred = ‘FORCED’ if a forced backup is active B.6.4 S TATUS C OMMANDS Status commands retrieve configuration, maintenance and alarm status in summary form. B.6.4.1 C ONFIGURATION S TATUS Command Details Configuration Status: Confirmation: >DEV/RCS_'cr' FRE_xxxxx.xxx'cr' Frequency ATT_yy.yy'cr' Attenuator RX_nnn'cr' Receive - ON/OFF/COLD ONL_nnn'cr' Online - ON/OFF RED_xx_yy_z'cr' See Note CLD_nnn'cr' Cold Start - ON/OFF AFR_nnn'cr' Auto Flt Recovery-ON/OFF EXT_xxx'cr''lf'] Ext. Ref. - YES/NO Note: If Redundancy OFF, xx_yy_z = OFF. If Redundancy ON and converter selected as backup controller, xx_yy_z = BU_yy where yy is the number of converters in the chain
Status:
(i.e. 01 to 12). If Redundancy ON and converter is selected as a chain unit xx is the
converter number (01 to 12), yy = P1 or P2 for single or dual polarity system, and z = A if
Auto Mode or M if Manual Mode.