Attenuator, Cold start, Mute – Comtech EF Data DT-4500 Series User Manual
Page 85: B.6.2.2 a, B.6.2.3 c, B.6.2.4 m
DT4500 Series Down Converters
MN/DT4500.IOM
Remote Control
Revision 1
67
B.6.2.2 A
TTENUATOR
The default is 10 dB.
Command
Details
Set Attenuator:
Confirmation: >DEV/ATT_yy.yy'cr'lf'] Retrieve Attenuator: Confirmation: >DEV/ATT_ yy.yy'cr''lf'] Note: yy.yy = 0.0 to 25.00 dB in 0.25 steps. B.6.2.3 C OLD S TART The cold start function, if enabled, mutes the output signal for a predetermined time Command Details Set Cold Start: xxx = ON or OFF Confirmation: >DEV/CLD_xxx'cr''lf'] Retrieve Status: Confirmation: >DEV/CLD_xxx'cr''lf'] B.6.2.4 M UTE The default is ON. Command Details Mute Output: xxx = ON or OFF Confirmation: >DEV/MUT_xxx'cr''lf'] Retrieve Mute Confirmation: >DEV/MUT_yyy'cr''lf'] yyy = ON/OFF/COLD
following Power-Up to ensure a stable reference oscillator (15 minutes). The default is
OFF. This command is disabled in redundant systems (i.e. COMMAND NOT
AVAILABLE).
Status: