Error response, End of message, Command ending – Comtech EF Data DT-4500 Series User Manual
Page 80: Response ending
DT4500 Series Down Converters
MN/DT4500.IOM
Remote Control
Revision 1
62
B.5.5 E
RROR
R
ESPONSE
If a converter cannot execute a Command or detects a protocol violation, an error
response is generated. An error is flagged by changing the "/" command designator in the
response to a "?". Following the "?" error symbol are two characters which are unique
error symbols useful for computer analysis. The two error symbols are followed by a text
string explaining the error for the convenience of a human operator. For this document,
ER is used for the generic case examples response.
Example:
>DEV?COM ER Error Message 'cr''lf']
B.5.6 E
ND
O
F
M
ESSAGE
End of message strings were devised in such a way that an orderly screen presentation
would result when converters are controlled by simple ASCII terminals.
B.5.6.1 C
OMMAND
E
NDING
The end of message for a command is a carriage return. For this document, 'cr' is used B.5.6.2 R ESPONSE E NDING End of message for a response is a carriage return, line feed and a bracket: 'cr''lf'].
for the carriage return.
Example:
Example: >DEV/COM_'cr''lf']