Errata b, Comtech ef data documentation update, Comments – Comtech EF Data DT-4500 Series User Manual
Page 4
Filename: T_ERRATA
1
Errata B
Comtech EF Data Documentation Update
Subject:
Added A.1.1.1 Packed Configuration Status
Date:
December 16, 2005
Document:
DT-4500 Series, Down Converters, Installation and Operation
Manual, Revision 1, dated June 15, 2005
Part Number:
MN/DT4500.EB1
Collating Instructions:
Attach this page to page 41
Comments:
Add paragraph A.1.1.1 to read:
Change Specifics:
A.1.1.1
Packed Configuration Status
Configuration
Status:
Confirmation:
>DEV/PACRCS_aaaabbbcdeffgghijkl'cr''lf']
where:
aaaa = # of 125kHz steps above base frequency
1
bbb = # of 0.25 dB steps above 0.00 dB
2
c = 1 if Transmitter ON, 0 if OFF, 2 if Cold
d = 1 if unit ONLINE, 0 if OFFLINE
e = 1 if Redundancy ON, else 0
ff = converter # (01-12,BU or 00 if e = 0)
gg = 00 if 'ff' is 00 (redundancy OFF)
gg = chain length (01-12) if 'ff' is BU
gg = XX if 'ff' = 01 - 12
h = A if Auto Mode, M if Manual
3
I = 1 if Cold Start Enabled, else 0
j = 1 if Auto recovery enabled, else 0
K = 1 if an Ext. Ref is present, else 0
l = 1 if Remote Mode, 0 if Local Mode
Notes:
1
If the converter is 1 kHz step size, this will be the number of 1 kHz steps above the
base frequency. Also, this will be 5 bytes(aaaaa) long for model 4513X converters
with 125 KHz frequency step size. This will be 7 bytes(aaaaaaa) long for all 1KHz
step size converters.
2
If the converter is 0.1 -dB step size, this will be the number of 0.1 -dB steps above
the base frequency
3
If it is a backup Converter, it is always ‘A’.
4
If it is the primary converter, gg = P1 or P2 (single or dual polarity system.