DT4500 Series Down Converters

MN/DT4500.IOM

Remote Control

Revision 1

70

Command

Details

Initialize Command:

_xx_yy'cr'

Confirmation: >DEV/ICT_xx_yy'cr''lf']

Initialize Status:

Confirmation: >DEV/ICT_xx_yy'cr''lf']

xx = chain position = 01 to 12, or BU. Where BUselects the

converter as the backup.

yy = chain length for xx = BU (i.e. Backup Converter) 01 to 12.

yy = P1 or P2, single or dual polarity

Example 1:

The following command assigns the converter chain position "1".

>DEV/ICT_01'cr''lf']

Example 2:

The following command assigns the receiving converter as the backup

converter in a 1:8 system.

>DEV/ICT_BU_08'cr''lf']
It should be reiterated that only the converter physically located at the top of a redundant
rack should be assigned as the Backup unit. Likewise, assignment of chain positions in a
redundant rack should be made according to the physical allocation of each converter in
the rack (i.e. The top converter should be the Backup, the second converter should be
assigned chain position 1, the third converter position 2, etc.).

B.6.3.2 A

UTOMATIC

/M

ANUAL

M

ODE

This command provides for automatic switching by the backup Converter if both units
are in the Redundancy Mode. This command is only accepted by the backup Converter.
If a chain converter is set in Manual Mode, the backup Converter will log the occurrence
and not act upon further information from the converter until put into Automatic Mode.
The default is off.

Command

Details

Automatic Mode:

_xx_y'cr'

Confirmation: >DEV/SAM_xx_y'cr''lf']

Automatic Status:

_xx_'cr'

Confirmation: >DEV/SAM_xx_y'cr''lf']

Where: xx = 01 to 12, converter number

y = A for Auto; M for Manual