Automatic configuration verification, A.3.2 a – Comtech EF Data DT-4500 Series User Manual
Page 68
DT4500 Series Down Converters
MN/DT4500.IOM
Redundant System Operation
Revision 1
50
In a single polarity system set “POL=1” on all online units. In a dual polarity system,
where the BU has a Polarity Switch Module (PSM) installed, configure each unit to
represent the RF feed it is connected to POL=1 or POL=2. See Figure 27.
A.3.2 A
UTOMATIC
C
ONFIGURATION
V
ERIFICATION
The backup Converter has a menu that allows the operator to choose, on a converter-by-
converter basis, manual (M) or automatic (A) operating mode.
Figure 30 shows the system configured for automatic (A) operation. In this mode, failure
of an online converter will automatically cause a switchover to the redundant unit to
occur. In the field, the simplest way to test this mode is to turn off an online unit. The
AUTO/MANUAL selection is made in the converter. The online units will report their
status as show in Figure 30.