beautypg.com

Comtech EF Data DT-4500 Series User Manual

Page 25

background image

DT4500 Series Down Converters

MN/DT4500.IOM

Introduction

Revision 1

7

Characteristic

Specification

Phase Noise

100 Hz

1 kHz

10 kHz

100 kHz

1 MHz

Limit (dBc/Hz)

-80

-89
-95
-105
-120

Typical (dBc/Hz)
-83
-92
-97
-109
-124

Remote Control (Rear Panel)

Comm Port RS-485 or RS-232

Indicators (Front Panel)
Power

On

Receive

Remote
On

Line

Stored

Fault

Fault


Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED

Test Points (Front Panel)
RF

Sample

IF

Sample

Optional L.O. Sample


SMA, -20 dBc Nominal
BNC, -20 dBc Nominal

Power
Voltage
Frequency
Dissipation
Power

Option


90 to 250 Vac, Autoranging, optional –48 VDC
47 to 63 Hz
60 Watts
-48 Vdc

Environmental
Temperature
Altitude
Humidity


0 to 50°C (32 to 122° F)
10,000 Feet MSL
0 to 95 % Relative

Physical
Width
Height
Depth
Weight


19 Inches

(48.26 cm)

1.75 Inches (4.44 cm)
22 Inches

(55.88 cm)

15 Pounds

(7.00 kg)

MTBF

49,740 hrs. (calculated)
>100,000 hrs. (field experience)

Summary Alarm

Relay Closure


Form C

This manual is related to the following products: