Command/response pairs, Utility commands, Time – Comtech EF Data DT-4500 Series User Manual
Page 81: Date, Physical address, Baud rate, B.6 c, B.6.1 u, B.6.1.1 t, B.6.1.2 d
DT4500 Series Down Converters
MN/DT4500.IOM
Remote Control
Revision 1
63
B.6 C
OMMAND
/R
ESPONSE
P
AIRS
B.6.1 U
TILITY
C
OMMANDS
B.6.1.1 T
IME
Command
Details
Set Time:
hh = Hour*
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
mm = Minutes ss = Seconds
Retrieve Time:
Confirmation: >DEV/TIM_hh:mm:ss'cr''lf']
* 24 hour military time is used.
B.6.1.2 D
ATE
Command
Details
Set Date:
mm = Month Confirmation: >DEV/DAT_mm/dd/yy'cr'lf'] dd = Day yy = Year Retrieve Date: Confirmation: >DEV/DAT_mm/dd/yy'cr''lf'] B.6.1.3 P HYSICAL A DDRESS The default Physical Address from is 1. Command Details Set Physical Address: xxx = 1 to 255 Confirmation: >DEV/SPA_xxx'cr''lf'] Retrieve Phys. Addr: Confirmation: >DEV/SPA_xxx'cr''lf'] B.6.1.4 B AUD R ATE The default baud rate is 9600. Command Details Set Baud Rate: xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4 Confirmation: >DEV/SBR_xxxx'cr''lf'] Retrieve Baud Rate: Confirmation: >DEV/SBR_xxxx'cr''lf']