Front panel display, Front panel test point samples, Prime power switch – Comtech EF Data DT-4500 Series User Manual
Page 34: New in this manual

DT4500 Series Down Converters
MN/DT4500.IOM
Introduction
Revision 1
16
1.5 F
RONT
P
ANEL
D
ISPLAY
The front panel display is a two line, 24-character, LCD display. Each configuration
function, or operating mode, is shown on the display when the operator enters a
command into the keypad on the front panel.
1.6 F
RONT
P
ANEL
T
EST
P
OINT
S
AMPLES
Two test point connections are located on the front panel for monitoring the RF input and
the IF output. An SMA connector is provided for the RF input, and a BNC connector is
provided for the IF output. There is also an optional RF LO monitor available that
replaces the RF monitor.
1.7 P
RIME
P
OWER
S
WITCH
The on/off prime power switch is located on the rear of the chassis adjacent to the prime
power input connector. The power switch contains a filter and dual fuse. The dual fuse
is rated for 2 Amps.
1.8 N
EW IN THIS
M
ANUAL
Incorporated Errata’s A though E
Incorporated new figure for TSEQM Connector Locations.