beautypg.com

Comtech EF Data DT-4500 Series User Manual

Page 26

background image

DT4500 Series Down Converters

MN/DT4500.IOM

Introduction

Revision 1

8

Table 3. DT-4503/X C-Band Down Converter Specifications

Characteristic

Specification

Frequency Range
DT-4503
DT-4503/D
DT-4503/E
Conversion
Step

Size

Preset

Channels

Stability Over Time

Stability Over Temp

3625 to 4200 MHz
3400 to 3700 MHz
Refer to Table 2.
Dual, No Inversion
125 kHz standard, 1kHz optional
32 Frequencies and Gains
± 1 x 10

-9

/Day

± 1 x 10

-8

0 to 50°C (32 to 122

o

F)

RF Input

Noise Figure

Level
Impedance
Return

Loss


11 dB Maximum at 0 dB Attenuation

-45 dBm Typical
50

20 dB Min. with RF/IF Connector Module

IF Output

Output Level

Range


Intermodulation

Non–carrier Spurious

Carrier Spurious

Impedance

Return

Loss


+20 dBm at 1 dB Compression
52 to 88 or 104 to 176 MHz), optional 50 to 80

MHz or 100 to 180 MHz, (see Note)

-60 dBc @ 0 dBm Output SCL
-80 dBm
-65 dBc @ +3 dBm Output
50 or 75

23 dB Min. with RF/IF connector module
or SW Module

Transfer

Gain

Attenuation Adjust

Gain Stability

Ripple: 70 MHz IFCF


140 MHz IFCF
Slope
Image

Rejection

AM to PM

IF

Bandwidth


45 dB ± 2 dB
0 to 20 in 0.25 dB Steps
0.1 dB Steps Optional
± 0.25 dB/Day
± 0.25 dB (± 18 MHz), optional ± 20 MHz,
(see

Note)

0.75 dB (± 36 MHz), optional ± 40 MHz, (see

Note) 10.05 dB/MHz

0.05 dB/MHz
-80 dB Inband
0.1

o

./ dB for Output up to –5 dBm

36 or 72 MHz), optional 40 or 80 MHz,
(see

Note)

External Ref.

Input 5 or 10 MHz @ +3dBm
Optional 10 MHz Rear Panel Reference Output

This manual is related to the following products: